{"id":251,"date":"2026-05-25T06:23:49","date_gmt":"2026-05-25T06:23:49","guid":{"rendered":"https:\/\/psd-carbon.com\/?p=251"},"modified":"2026-10-15T06:43:48","modified_gmt":"2026-10-15T06:43:48","slug":"psd-ag-charbon-de-noix-de-coco-enrichi-en-argent","status":"publish","type":"post","link":"https:\/\/psd-carbon.com\/fr\/psd-ag-silver-loaded-coconut-carbon\/","title":{"rendered":"Charbon actif \u00e0 base de coques de noix de coco enrichi en argent pour la filtration de l'eau"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Caract\u00e9ristiques techniques<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">Param\u00e8tre<\/th><th class=\"has-text-align-left\" data-align=\"left\">PSD-Ag+<\/th><th class=\"has-text-align-left\" data-align=\"left\">Unit\u00e9<\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Indice d'iode<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt; 1 100<\/td><td class=\"has-text-align-left\" data-align=\"left\">mg\/g<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Teneur en humidit\u00e9<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 10<\/td><td class=\"has-text-align-left\" data-align=\"left\">wt%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Teneur en cendres<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 3<\/td><td class=\"has-text-align-left\" data-align=\"left\">wt%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Densit\u00e9 d'emballage<\/td><td class=\"has-text-align-left\" data-align=\"left\">430 \u2013 530<\/td><td class=\"has-text-align-left\" data-align=\"left\">kg\/m\u00b3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">pH<\/td><td class=\"has-text-align-left\" data-align=\"left\">5 \u2013 8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Duret\u00e9<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt; 95<\/td><td class=\"has-text-align-left\" data-align=\"left\">%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Surface sp\u00e9cifique (BET)<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt; 1 000<\/td><td class=\"has-text-align-left\" data-align=\"left\">m\u00b2\/g<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Taille grande sur mailles n\u00b0 12 (1,70 mm)<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 10<\/td><td class=\"has-text-align-left\" data-align=\"left\">wt%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Fines passant au tamis de 40 mesh (0,43 mm)<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 5<\/td><td class=\"has-text-align-left\" data-align=\"left\">wt%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Chargement de l'argent<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.05\u20130.10 (0.5 \u2013 1)<\/td><td class=\"has-text-align-left\" data-align=\"left\">wt% (\u2030)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Les m\u00e9thodes d'essai sont conformes aux normes GB, JIS ou ASTM applicables. La surface sp\u00e9cifique est mesur\u00e9e selon la m\u00e9thode BET. Les valeurs indiqu\u00e9es correspondent \u00e0 des moyennes typiques par lot. Les sp\u00e9cifications finales du produit et les crit\u00e8res d'acceptation doivent \u00eatre confirm\u00e9s dans la fiche technique convenue.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Applications et s\u00e9lection<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Cartouches filtrantes pour l'eau au point d'utilisation (POU)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Utilisation :<\/strong> Cartouches filtrantes pour l'eau potable au point d'utilisation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exigences du client :<\/strong> Associer l'adsorption par charbon actif \u00e0 une action antibact\u00e9rienne au sein du m\u00e9dia filtrant, lorsque la ma\u00eetrise de la prolif\u00e9ration bact\u00e9rienne fait partie des crit\u00e8res de conception.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques pertinentes du produit :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Un indice d'iode &gt; 1 100 mg\/g et une surface sp\u00e9cifique BET &gt; 1 000 m\u00b2\/g constituent les principaux param\u00e8tres li\u00e9s \u00e0 l'adsorption.<\/li>\n\n\n\n<li>Teneur en argent comprise entre 0,5 et 1 \u2030, conform\u00e9ment au cahier des charges du produit.<\/li>\n\n\n\n<li>Efficacit\u00e9 antibact\u00e9rienne test\u00e9e par SGS, avec une r\u00e9duction bact\u00e9rienne sup\u00e9rieure \u00e0 99% contre trois souches d'essai sp\u00e9cifi\u00e9es, conform\u00e9ment \u00e0 la norme ASTM E2149-2013, dans des conditions de contact dynamique avec un temps de contact de 24 heures.<\/li>\n\n\n\n<li>R\u00e9partition granulom\u00e9trique contr\u00f4l\u00e9e en vue de l'\u00e9valuation par rapport \u00e0 la conception de la cartouche.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les performances du filtre final doivent \u00eatre \u00e9valu\u00e9es dans les conditions d'utilisation pr\u00e9vues.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Filtration de l'eau au point d'entr\u00e9e (POE) \/ Filtration de l'eau dans toute la maison<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Utilisation :<\/strong> Syst\u00e8mes POE et syst\u00e8mes de filtration d'eau pour toute la maison.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exigences du client :<\/strong> Choisissez un m\u00e9dia filtrant pr\u00e9sentant des propri\u00e9t\u00e9s d'adsorption, une distribution granulom\u00e9trique et des caract\u00e9ristiques physiques adapt\u00e9es \u00e0 la conception du lit filtrant et aux conditions de fonctionnement pr\u00e9vues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques pertinentes du produit :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Indice d'iode &gt; 1 100 mg\/g et surface sp\u00e9cifique BET &gt; 1 000 m\u00b2\/g.<\/li>\n\n\n\n<li>Duret\u00e9 &gt; 95% et densit\u00e9 apparente comprise entre 430 et 530 kg\/m\u00b3, conform\u00e9ment aux sp\u00e9cifications indiqu\u00e9es.<\/li>\n\n\n\n<li>Fractions surdimensionn\u00e9es retenues par un tamis de 12 mesh (1,70 mm) &lt; 10 % en poids et fractions fines passant \u00e0 travers un tamis de 40 mesh (0,43 mm) &lt; 5 % en poids.<\/li>\n\n\n\n<li>Teneur en argent comprise entre 0,5 et 1 \u2030 et r\u00e9sultats de tests antibact\u00e9riens attest\u00e9s.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Le choix final doit tenir compte du d\u00e9bit, de la profondeur du lit, du temps de contact, de la perte de charge et des exigences de performance du syst\u00e8me de filtration final.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Syst\u00e8mes de filtration de l'eau potable<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Utilisation :<\/strong> R\u00e9seaux municipaux et nationaux de filtration de l'eau potable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Exigences du client :<\/strong> \u00c9valuer les mat\u00e9riaux filtrants qui allient l'adsorption des contaminants \u00e0 des propri\u00e9t\u00e9s antibact\u00e9riennes, tout en respectant les exigences applicables en mati\u00e8re de qualit\u00e9 de l'eau et de s\u00e9curit\u00e9 des mat\u00e9riaux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Caract\u00e9ristiques pertinentes du produit :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Indice d'iode &gt; 1 100 mg\/g, surface sp\u00e9cifique BET &gt; 1 000 m\u00b2\/g, et propri\u00e9t\u00e9s physiques sp\u00e9cifi\u00e9es.<\/li>\n\n\n\n<li>Teneur en argent comprise entre 0,5 et 1 \u2030.<\/li>\n\n\n\n<li>R\u00e9sultats des tests antibact\u00e9riens r\u00e9alis\u00e9s par SGS sur trois souches bact\u00e9riennes sp\u00e9cifiques.<\/li>\n\n\n\n<li>Sp\u00e9cifications techniques et documentation d'essais pertinente \u00e0 l'appui de l'\u00e9valuation du produit.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La compatibilit\u00e9 avec un r\u00e9seau d'eau potable sp\u00e9cifique doit \u00eatre v\u00e9rifi\u00e9e en fonction de la conception finale du filtre, de la composition chimique de l'eau, des exigences en mati\u00e8re de lib\u00e9ration d'argent, ainsi que des exigences r\u00e9glementaires ou de certification applicables.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Autres applications<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les applications potentielles \u00e0 \u00e9valuer comprennent l'eau destin\u00e9e aux boissons et au brassage, l'eau utilis\u00e9e dans l'industrie agroalimentaire, les syst\u00e8mes d'eau ultra-pure (UPW) pour les semi-conducteurs, ainsi que les syst\u00e8mes d'eau \u00e0 usage m\u00e9dical et pharmaceutique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'ad\u00e9quation de l'application doit \u00eatre \u00e9valu\u00e9e au cas par cas en fonction de la qualit\u00e9 de l'eau vis\u00e9e, de la compatibilit\u00e9 des mat\u00e9riaux, des exigences en mati\u00e8re de lib\u00e9ration d'argent et des normes applicables au produit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Preuves techniques et assurance qualit\u00e9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Efficacit\u00e9 antibact\u00e9rienne certifi\u00e9e par SGS<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le charbon actif charg\u00e9 d'argent PSD-Ag+ a \u00e9t\u00e9 test\u00e9 par SGS conform\u00e9ment \u00e0 la norme ASTM E2149-2013a dans des conditions de contact dynamique avec une dur\u00e9e de contact de 24 heures.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Selon le rapport d'essai SGS ASH19-035724-01, publi\u00e9 le 16 juillet 2025, l'\u00e9chantillon test\u00e9 a permis une r\u00e9duction bact\u00e9rienne sup\u00e9rieure \u00e0 99% vis-\u00e0-vis des trois souches d'essai suivantes :<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">Organisme d'essai<\/th><th class=\"has-text-align-left\" data-align=\"left\">Souche<\/th><th class=\"has-text-align-left\" data-align=\"left\">R\u00e9duction de la charge bact\u00e9rienne<\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Staphylococcus aureus<\/td><td class=\"has-text-align-left\" data-align=\"left\">ATCC 6538<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt;99%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Escherichia coli<\/td><td class=\"has-text-align-left\" data-align=\"left\">ATCC 25922<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt;99%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pseudomonas aeruginosa<\/td><td class=\"has-text-align-left\" data-align=\"left\">ATCC 9027<\/td><td class=\"has-text-align-left\" data-align=\"left\">&gt;99%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ces r\u00e9sultats s'appliquent \u00e0 l'\u00e9chantillon test\u00e9 dans les conditions d'essai indiqu\u00e9es. Les performances d'un filtre \u00e0 eau fini peuvent varier en fonction de la conception de la cartouche, de la charge en charbon, du d\u00e9bit, de la composition chimique de l'eau et des conditions de fonctionnement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e9sum\u00e9 du rapport d'essai SGS est disponible sur simple demande.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Avantages techniques<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. Base de charbon actif issu de coques de noix de coco<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le PSD-Ag+ utilise du charbon actif issu de coques de noix de coco pr\u00e9sentant un indice d'iode sup\u00e9rieur \u00e0 1 100 mg\/g et une surface sp\u00e9cifique BET sup\u00e9rieure \u00e0 1 000 m\u00b2\/g. Ces param\u00e8tres caract\u00e9risent les propri\u00e9t\u00e9s d'adsorption du charbon et permettent d'\u00e9valuer son aptitude aux applications de filtration de l'eau. Les performances d'\u00e9limination de contaminants sp\u00e9cifiques doivent \u00eatre confirm\u00e9es dans des conditions d'essai appropri\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Impr\u00e9gnation contr\u00f4l\u00e9e d'argent ch\u00e9lat\u00e9<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'argent est incorpor\u00e9 au moyen d'un proc\u00e9d\u00e9 contr\u00f4l\u00e9 d'impr\u00e9gnation par ch\u00e9lation. La teneur en argent est fix\u00e9e entre 0,5 et 1 \u2030 et contr\u00f4l\u00e9e conform\u00e9ment au cahier des charges du produit. Les certificats d'analyse (COA) par lot sont disponibles conform\u00e9ment aux conditions d'approvisionnement convenues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. Efficacit\u00e9 antibact\u00e9rienne certifi\u00e9e par SGS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les essais r\u00e9alis\u00e9s par SGS conform\u00e9ment \u00e0 la norme ASTM E2149-2013a ont montr\u00e9 une r\u00e9duction bact\u00e9rienne sup\u00e9rieure \u00e0 99% face \u00e0 trois souches d'essai sp\u00e9cifi\u00e9es, dans des conditions de contact dynamique pendant 24 heures. Veuillez vous reporter aux r\u00e9sultats d'essai ci-dessus pour conna\u00eetre la m\u00e9thode d'essai et les conclusions rapport\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4. Gestion de la qualit\u00e9 et documentation<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les op\u00e9rations de fabrication sont g\u00e9r\u00e9es conform\u00e9ment aux syst\u00e8mes de gestion ISO 9001, ISO 14001 et ISO 45001. La documentation relative au certificat d'analyse (COA) par lot et le r\u00e9sum\u00e9 du rapport d'essai antibact\u00e9rien de SGS sont disponibles conform\u00e9ment aux conditions de fourniture convenues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour la certification NSF, veuillez vous reporter au certificat correspondant afin de conna\u00eetre la norme exacte, le produit certifi\u00e9 et le champ d'application.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment \u00e7a marche ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Phase d'adsorption<\/strong>: La structure poreuse du charbon actif permet d'adsorber certains contaminants pr\u00e9sents dans l'eau. L'efficacit\u00e9 r\u00e9elle de l'\u00e9limination d\u00e9pend du contaminant vis\u00e9, de la composition chimique de l'eau, du temps de contact et de la conception du filtre.<\/li>\n\n\n\n<li><strong>Fonction antibact\u00e9rienne<\/strong>: L'incorporation d'argent renforce la fonction antibact\u00e9rienne pr\u00e9vue du m\u00e9dia filtrant. Les essais r\u00e9alis\u00e9s par SGS ont montr\u00e9 une r\u00e9duction bact\u00e9rienne sup\u00e9rieure \u00e0 99% face \u00e0 trois souches d'essai sp\u00e9cifiques, dans les conditions de contact dynamique de 24 heures indiqu\u00e9es. Les performances d'un filtre fini doivent \u00eatre \u00e9valu\u00e9es en fonction de l'application pr\u00e9vue et des conditions de fonctionnement.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Informations relatives aux march\u00e9s publics<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Conditionnement :<\/strong> Sacs de 20 kg \/ sacs en vrac de 500 kg.<\/li>\n\n\n\n<li><strong>Personnalisation :<\/strong> Teneur en argent comprise dans la fourchette sp\u00e9cifi\u00e9e de 0,5 \u00e0 1 \u2030 ; les autres exigences relatives \u00e0 la teneur en argent sont soumises \u00e0 un examen technique, ainsi que les sp\u00e9cifications concernant la taille des particules et les options de conditionnement. Les sp\u00e9cifications d\u00e9finitives sont confirm\u00e9es dans la fiche technique (TDS) convenue.<\/li>\n\n\n\n<li><strong>Documentation technique :<\/strong> Le TDS, le certificat d'analyse (COA) par lot et le r\u00e9sum\u00e9 du rapport d'essai antibact\u00e9rien SGS sont disponibles conform\u00e9ment aux conditions de fourniture convenues.<\/li>\n\n\n\n<li><strong>\u00c9chantillons et d\u00e9lais de livraison :<\/strong> Contactez-nous pour v\u00e9rifier la disponibilit\u00e9 des \u00e9chantillons et conna\u00eetre les d\u00e9lais de livraison actuels, en fonction des sp\u00e9cifications requises et de la quantit\u00e9 command\u00e9e.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Vous envisagez d'utiliser du charbon actif impr\u00e9gn\u00e9 d'argent pour votre filtre \u00e0 eau ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Veuillez nous indiquer l'application vis\u00e9e, la taille de particules requise, la charge d'argent pr\u00e9vue et les conditions de fonctionnement envisag\u00e9es.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Purestar peut vous aider \u00e0 analyser vos besoins et vous fournir les caract\u00e9ristiques techniques des produits disponibles, la documentation d'essai correspondante ainsi que des informations sur les \u00e9chantillons.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-black-color has-text-color has-background has-link-color wp-element-button\" href=\"https:\/\/psd-carbon.com\/fr\/nous-contacter\/\" style=\"background-color:#4caf50\"><strong>Demander un \u00e9chantillon<\/strong><\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Technical Specifications Parameter PSD-Ag+ Unit Iodine value &gt; 1,100 mg\/g Moisture content &lt; 10 wt% Ash content &lt; 3 wt% Packing density 430 \u2013 530 kg\/m\u00b3 pH 5 \u2013 8 \u2014 Hardness &gt; 95 % Specific surface area (BET) &gt; 1,000 m\u00b2\/g Oversize on 12 mesh (1.70 mm) &lt; 10 wt% Fines passing 40 mesh [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8,24],"tags":[49],"class_list":["post-251","post","type-post","status-publish","format-standard","hentry","category-coconut-shell-activated-carbon","category-impregnated-activated-carbon","tag-psd-ag"],"acf":[],"_links":{"self":[{"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/posts\/251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/comments?post=251"}],"version-history":[{"count":12,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/posts\/251\/revisions"}],"predecessor-version":[{"id":2266,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/posts\/251\/revisions\/2266"}],"wp:attachment":[{"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/media?parent=251"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/categories?post=251"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/psd-carbon.com\/fr\/wp-json\/wp\/v2\/tags?post=251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}